Research Article

Analyzed and Simulated Prediction of Emission Characteristics of Construction Dust Particles under Multiple Pollution Sources

Table 2

Concentrations of dust at different monitoring points of work areas.

Construction periodsDust monitoring pointsDust typesAverage concentration (mg/m3)Scope of excess multipleMeasurement point yield (%)Variance

FoundationFoundation excavation areaSilicious dust a0.9880.000–0.32072.0000.042
Rebar processing areaSilicious dust a1.1030.000–0.59070.0000.082
Concrete mixing areaCement dust b7.3920.000–3.44037.00010.017
Road areaSilicious dust a4.2870.000–5.65013.0003.391

Structural frameFloor areaSiliciousdust a1.1480.000–0.60060.0000.066
Concrete mixing areaCement dust b2.093100.0000.791
Rebar processing areaSilicious dust a1.3740.000–0.74038.0000.127
Timber formwork areaTimber dust c8.6970.000–3.74012.0004.855
Road areaSilicious dust a2.1240.000–2.20030.0000.860

Note. The concentration of silicious dust, cement dust, and timber dust is a, PC-PWA = 1 mg/m3, b, PC-PWA = 4 mg/m3, and c, PC-PWA = 3 mg/m3 [35], respectively.