Research Article
[Retracted] Model Test and Numerical Simulation of Water Conservancy Foundation Bearing Capacity
Table 7
Vertical compressive static load test results of single pier.
| Test pier no. | Pier length (m) | Pier diameter (mm) | Area of pressure bearing plate (m2) | Ultimate bearing capacity (kN) | Maximum settlement (mm) | Characteristic value of bearing capacity (kN) | Corresponding settlement (mm) |
| 1-3 | 13 | 1000 | 0.63 | 494 | 45.00 | 247.4 | 15.76 | 2-3 | 13 | 1000 | 0.63 | 724 | 40.00 | 361.4 | 14.96 | 3-3 | 13 | 1200 | 0.94 | 1176 | 46.00 | 588.4 | 15.85 |
|
|