Research Article
Deep Learning-Aided Automated Pneumonia Detection and Classification Using CXR Scans
Table 8
Correctly, incorrectly, and not detected among the three classes.
| Network | Training and test ratio | COVID-19 | Regular pneumonia | Normal | Correctly detected | Incorrectly detected | Not detected | Correctly detected | Incorrectly detected | Not detected | Correctly detected | Incorrectly detected | Not detected |
| CNN | 80–20% | 243 | 1 | 13 | 239 | 5 | 20 | 294 | 29 | 29 | 70–30% | 335 | 3 | 29 | 378 | 54 | 12 | 409 | 19 | 35 | 60–40% | 482 | 14 | 30 | 480 | 16 | 40 | 576 | 56 | 16 |
| Xception | 80–20% | 244 | 1 | 12 | 226 | 13 | 33 | 291 | 35 | 5 | 70–30% | 357 | 3 | 27 | 343 | 33 | 47 | 433 | 50 | 11 | 60–40% | 486 | 13 | 26 | 435 | 15 | 85 | 588 | 87 | 4 |
| VGG19 | 80–20% | 244 | 0 | 12 | 216 | 3 | 43 | 295 | 53 | 1 | 70–30% | 360 | 1 | 24 | 331 | 17 | 59 | 438 | 71 | 6 | 60–40% | 476 | 9 | 38 | 580 | 87 | 12 | 443 | 31 | 77 |
| VGG16 | 80–20% | 243 | 1 | 13 | 212 | 5 | 4 | 296 | 54 | 0 | 70–30% | 361 | 4 | 23 | 343 | 9 | 47 | 440 | 61 | 4 | 60–40% | 466 | 11 | 46 | 386 | 4 | 134 | 592 | 165 | 0 |
|
|