Evaluation indexes of the effect of the integrated model on test set image recognition.
| Model | Accuracy (%) | Precision (%) | Recall rate (%) | AUC |
| VGG19 + inception V3 | 83.27 | 79.46 | 88.68 | 0.84 | VGG19 + DenseNet161 | 88.35 | 85.45 | 89.52 | 0.88 | Inception V3 + DenseNet161 | 89.78 | 87.78 | 94.57 | 0.90 |
|
|