GRADE evidence profile—gFOBT versus FIT.

Quality assessmentNumber of patientsEffectQualityImportance
Number of studiesDesignRisk of biasInconsistencyIndirectnessImprecisionOther considerationsFITgFOBTRelative (95% CI)Absolute

Complications from tests
1Randomized trialNot seriousNot seriousNot seriousSerious1Not seriousNot pooled⨁⨁⨁◯ 
Moderate
Critical

CRC/advanced adenoma detection rate (ITS)
5Randomized trialsNot seriousNot seriousSerious2Not seriousNot serious278/24,288 (1.1%)129/27,346 (0.5%)RR 2.15 (1.58–2.94)5 more per 1000 (from 3 more to 9 more)⨁⨁⨁◯ 
Moderate
Important

CRC/advanced adenoma detection rate (PP)
5Randomized trialsNot seriousNot seriousSerious2Not seriousNot serious278/12,146 (2.3%)129/10,976 (1.2%)RR 1.83 (1.30–2.57)10 more per 1000 (from 4 more to 18 more)⨁⨁⨁◯ 
Moderate
Important

False-positive screening test results
5Randomized trialsNot seriousSerious3Not seriousNot seriousNot serious385/24,288 (1.6%)188/27,346 (0.7%)RR 2.12 (1.02–4.39)8 more per 1000 (from 0 fewer to 23 more)⨁⨁⨁◯ 
Moderate
Important

Participation rate
6Randomized trialsNot seriousSerious4Not seriousNot seriousNot serious12,271/24,490 (50.1%)11075/27,548 (40.2%)RR 1.16 (1.05–1.28)64 more per 1000 (from 20 more to 113 more)⨁⨁⨁◯ 
Moderate
Important

CI: confidence interval; CRC: colorectal cancer; FIT: fecal immunochemical test; gFOBT: guaiac fecal occult blood test; GRADE: Grading of Recommendations, Assessment, Development and Evaluations; ITS: intention to screen; PP: per protocol; RR: relative risk.
1Only one study.
2Surrogate outcome for CRC mortality.
3Heterogeneity: Tau2 = 0.61; Chi2 = 56.96, df = 3 (); = 93%.
4Heterogeneity: Tau2 = 0.01; Chi2 = 107.18, df = 5 (); = 95%.