Research Article

Improving the Performance of the Prony Method Using a Wavelet Domain Filter for MRI Denoising

Table 1

SNR between the original and the denoised images corresponding to the two filters and values.

 

Original errors 29.77391 23.7840 16.0170 12.0372 8.9663
Kazubek's algorithm 33.7311 27.9346 20.4575 17.0542 14.1045
Modification to Kazubek's algorithm 34.0501 28.3961 21.4209 18.0140 15.3410