Summary of the position correlation between the endoleak and the local wall stress peak through the presentation of the matching index calculation.

 Angle of endoleak to SGCAngle of WS to SGCMatching index (%)

Model I265.1230.914.8
Model II87.891.94.4
Model III275.2244.712.5
Model IV203.1214.35.2
Model V8.5336.99.4