Research Article
Wavelet Scattering Transform for ECG Beat Classification
Table 7
The confusion matrices for the 4th time window combined with the NN, PNN, and KNN across 10 folds.
| | Original | Predicted | N | S | V | F | PPV (%) | SEN (%) | SPEC (%) |
| NN | N | 88146 | 811 | 789 | 254 | 93.8 | 97.9 | 97.8 | S | 3181 | 85641 | 901 | 277 | 94.9 | 95.2 | 98.3 | V | 1553 | 1323 | 85084 | 2040 | 94.4 | 94.5 | 98.1 | F | 1108 | 2439 | 3343 | 83110 | 97.0 | 92.3 | 97.5 |
| PNN | N | 86415 | 2540 | 615 | 430 | 99.8 | 96.0 | 99.9 | S | 171 | 89828 | 0 | 1 | 97.2 | 99.8 | 99.0 | V | 1 | 71 | 89879 | 49 | 99.3 | 99.9 | 99.8 | F | 0 | 1701 | 1645 | 86654 | 96.0 | 96.3 | 98.8 |
| KNN | N | 88915 | 644 | 281 | 160 | 98.5 | 98.8 | 99.5 | S | 893 | 87177 | 1155 | 775 | 92.7 | 96.9 | 97.4 | V | 496 | 4545 | 82247 | 2712 | 96.4 | 91.4 | 98.9 | F | 0 | 3 | 0 | 89997 | 99.5 | 100 | 100 |
|
|