The average SNR and RMSE of the denoising results of different noise types.

Original SNREMBWMAEM+BWEM+MABW+MAEM+BW+MAAverage

0 dBSNR28.426530.875536.445528.368328.340528.627427.863929.8497
RMSE0.01760.00580.00870.01320.00370.01320.01280.0107

1.25 dBSNR32.863233.747831.167031.731031.911332.300931.772632.2134
RMSE0.01210.01010.01570.01120.00890.01510.01450.0125

5 dBSNR60.018566.960757.680758.448059.548262.501958.845360.5719
RMSE0.01090.00460.00650.00580.00680.00880.00760.0073