Research Article
Mortality prediction in ICU Using a Stacked Ensemble Model
Table 7
Performance of different methods based on two feature sets.
| Feature set | Model | Precision | Recall | AUC | F-scores |
| SetS | LR | 0.914 | 0.633 | 0.632 | 0.564 | NB | 0.745 | 0.635 | 0.745 | 0.632 | RF | 0.677 | 0.714 | 0.677 | 0.712 | XGB | 0.924 | 0.823 | 0.862 | 0.823 | SEM | 0.924 | 0.831 | 0.879 | 0.824 | SetT | LR | 0.623 | 0.654 | 0.648 | 0.634 | NB | 0.612 | 0.65 | 0.636 | 0.651 | RF | 0.734 | 0.735 | 0.721 | 0.712 | XGB | 0.812 | 0.856 | 0.823 | 0.823 | SEM | 0.816 | 0.862 | 0.860 | 0.845 |
|
|