Research Article
Multisemantic Level Patch Merger Vision Transformer for Diagnosis of Pneumonia
Table 1
Result comparison between models: accuracy.
| Model | ViT | Patch merger | Patch fuser | Label smoothing | Image enhancement | Accuracy |
| M1 | X | X | X | X | X | 0.868590 | M2 | ✓ | X | X | X | X | 0.777244 | M3 | ✓ | ✓ | X | X | X | 0.889423 | MP-ViT | ✓ | ✓ | ✓ | X | X | 0.897436 | Final model | ✓ | ✓ | ✓ | ✓ | ✓ | 0.911859 |
|
|