Research Article
Pulmonary Nodule Detection Based on Multiscale Feature Fusion
| Experimental items | Parameter |
| Platform | Colab | Server system | Ubuntu | GPU | K80 | Momentum coefficient | 0.9 | Batch size | 64 | Weight attenuation coefficient | 0.0005 | Dropout rate | 0.5 | Anchor box sizes | , , , , , , , , | Learning rate | 0.001 | Scales of 3D patch of nodules | , , |
|
|