Research Article

Pulmonary Nodule Detection Based on Multiscale Feature Fusion

Table 6

Detection results of multiscale Faster R-CNN.

Diameter of nodules (mm)Number of detectionsNumber of missed testsSensitivity

3~5193597.4%
5~10243398.8%
10~20970100%
>20180100%