Parameters of liquid cargo tanks for thermal load calculation.
| Name | Value | Name | Value |
| Liquid capacity | 41743.5 | Surface area of cargo tank | 7028 | Tanker waterline external surface area | 3968 | The surface area of the liquid cargo ship | 3060 | Surface area of fuel channel | 93.6 | Surface area of ballast tank | 3536 | Isolated space side area | 230 | Main shielding thickness | 0.7 mm | Main shielding thermal conductivity | 45 W/(m⋅K) | Main insulation thickness | 230 mm | Thermal conductivity of the main insulation layer | 0.04 W/(m⋅K) | Secondary shielding thickness | 0.7 mm | Secondary shielding thermal conductivity | 45 W/(m⋅K) | Secondary insulation thickness | 300 mm | Secondary insulation thermal conductivity | 0.04 W/(m⋅K) | Resin thickness | 10 mm | Thermal conductivity of resin layer | 0.302 W/(m⋅K) | Thickness of tank inner shell | 20 mm | Thermal conductivity of tank inner shell | 45 W/(m⋅K) | Fuel temperature | 40 | Sea water heat exchange coefficient | 2908 W/(m⋅K) | Fuel heat transfer coefficient | 2368 W/(m2⋅K) |
|
|