Research Article

Determination of Fire Resistance of Eccentrically Loaded Reinforced Concrete Columns Using Fuzzy Neural Networks

Table 1

Actual and predicted value of fire resistance time for RC columns obtained with the ANFIS checking data.

Checking data
Column dimensionsThickness of the protective concrete layerPercentage of reinforcementAxial load coefficientBending moment coefficientFire resistance time of eccentrically loaded RC columns
Actual valuesPredicted values (ANFIS)

30.0030.002.001.000.100.25.885.53
30.0030.002.001.000.300.32.141.87
30.0030.003.001.000.100.52.943.44
30.0030.003.001.000.400.41.321.32
30.0030.004.001.000.400.12.081.83
40.0040.002.001.000.100.27.767.98
40.0040.002.001.000.4003.823.83
40.0040.003.001.000.200.43.563.74
40.0040.003.001.000.300.52.162.28
40.0040.003.001.000.4003.83.77
40.0040.004.001.000.100.110.149.9
40.0040.004.001.000.300.33.443.61
40.0040.003.000.600.200.25.565.52
40.0040.003.001.500.1001211.7
40.0040.003.001.500.500.41.381.28
50.0050.002.001.000.100.39.8310.1
50.0050.003.001.000.100.55.285.59
50.0050.004.001.000.300.43.843.61
50.0050.002.000.600.200.19.59.03
50.0050.002.000.600.5003.183.37
50.0050.004.000.600.300.25.75.53
50.0050.004.000.600.5003.523.53
50.0050.004.000.600.500.13.143.13
50.0050.004.000.600.500.22.82.81
50.0050.004.000.600.500.32.322.52
50.0050.004.000.600.500.41.882.2
50.0050.004.000.600.500.51.481.86