Research Article

Statistical Identification of Parameters for Damaged FGM Structures with Material Uncertainties in Thermal Environment

Table 5

Means of material elastic moduli and volume fraction index for different cases of uncertainty.

Temperature Parameters
(Given values)
SR and MNSR onlyMN only
Level 1
(1% SR 0.1% MN)
Level 2
(1% SR 0.5% MN)
Level 3
(5% SR 0.1% MN)
Level 4
(5% SR 0.5% MN)
1%5%0.1%0.5%

FGM beam through its thickness

= 300 k

= 600 k

FGM beam along its axial direction

= 300 k

= 600 k