Review Article

Sizing of a Standalone PV System with Battery Storage for a Dairy: A Case Study from Chile

Table 5

Success rates SR%, corrected peak power , and corrected battery storage capacity values for different values of the autonomy factor for the proposed stochastic methodology.

d11, 522, 533, 544, 55

SR%3970849497100100100100
(kWp)72.2279.8586.2891.9597.07101.79106.17110.29114.2
(kAh)1.721.902.052.192.312.422.522.622.72