Review Article

Sizing of a Standalone PV System with Battery Storage for a Dairy: A Case Study from Chile

Table 7

Success rates SR% for all months of the year in order to achieve at least 95% and 99% of system autonomy.

  (kWp) (kAh)SR%
JanFebMarAprMayJunJulAugSepOctNovDec

Noncritical loads397.072.3110010010010096979910010010010099
Critical loads4106.172.5210010010010099100100100100100100100