Research Article
[Retracted] A Hemodynamic-Based Evaluation of Applying Different Types of Coronary Artery Bypass Grafts to Coronary Artery Aneurysms
Table 1
The results of the mesh independency test on WSS and pressure.
| Number of meshes | Percent change of the parameter values | SVG | LIMA | WSS (Pa) | Pressure (mmHg) | WSS (Pa) | Pressure (Pa) |
| 200,000 | | 0.626 | 77.912 | 0.639 | 79.038 |
| 400,000 | ε | 0.599 | 86.293 | 0.623 | 86.395 | 4.30% | 10.70% | 2.50% | 9.30% |
| 600,000 | ε | 0.621 | 82.629 | 0.62 | 82.547 | 3.60% | 4.20% | 0.50% | 4.50% |
| 800,000 | ε | 0.61 | 84.324 | 0.608 | 84.672 | 1.80% | 2.00% | 1.90% | 2.60% |
| 1,000,000 | ε | 0.607 | 84.197 | 0.609 | 84.925 | 0.50% | 0.20% | 0.16% | 0.30% |
|
|
ε is the percentage change of the parameter value (WSS and pressure) due to the increase in the number of meshes.
|