Research Article
An Extended FMEA Model for Exploring the Potential Failure Modes: A Case Study of a Steam Turbine for a Nuclear Power Plant
Table 4
Results of the modified TOPSIS calculation.
| | FMi | | | RCi | Ranking |
| | FM1 | 0.0915 | 0.0386 | −0.0329 | 11 | | FM2 | 0.0441 | 0.0925 | 0.0271 | 4 | | FM3 | 0.0415 | 0.0943 | 0.0298 | 3 | | FM4 | 0.0481 | 0.1163 | 0.0386 | 2 | | FM5 | 0.0738 | 0.0581 | −0.0108 | 8 | | FM6 | 0.0568 | 0.0769 | 0.0104 | 5 | | FM7 | 0.0709 | 0.0628 | −0.0063 | 7 | | FM8 | 0.0598 | 0.0708 | 0.0050 | 6 | | FM9 | 0.0396 | 0.1083 | 0.0391 | 1 | | FM10 | 0.1182 | 0.0478 | −0.0436 | 12 | | FM11 | 0.0894 | 0.0522 | −0.0237 | 9 | | FM12 | 0.0933 | 0.0409 | −0.0326 | 10 |
|
|