Tab 3
/
Research Article
A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile
Table 3
Data of UPQC placement and reconfiguration for the 84-bus network.
Tie switches
Total losses (KW)
Voltage deviation
V
min
(PU)
V
ave
(PU)
Case 1
84–96
532.61
0.03078
0.9285
0.9692
Case 2
7, 13, 34, 39, 42, 55, 62, 72, 83, 86, 89, 90, 92
470.26
0.0248
0.9532
0.9752
Case 3
7, 13, 34, 39, 42, 55, 64, 72, 86, 89, 90, 91,92
407.43
0.0199
0.9531
0.9801
Case 4
14, 20, 34, 39, 42, 54, 59, 71, 86, 88, 90, 92, 96
624.58
0.0129
0.948
0.9888
Case 5
6, 34, 39, 42, 54, 64, 72, 81, 86, 88, 89, 90, 92
459.32
0.0147
0.9531
0.9854