Research Article

Usefulness of Positron Emission Tomography in the Examination of Hilar and Mediastinal Lymphadenopathies in Patients with Suspicion of Lung Cancer

Table 2

CT and PET validity parameters versus histology (gold standard), using lymph nodes as the study unit.

ABiopsy +Biopsy −Total

CT +7074144
CT −95059
Total79124203
PET +7678154
PET −44549
Total80123203

BBiopsy +Biopsy −Total
PET +7994173
PET −03030
Total79124203

CCTPET APET B
S0.890.951
SP0.400.370.24
PPV0.490.490.46
NPV0.850.921
Percentage agreement and 0.207 ()0.241 ()0.189 ()

(A) Preestablished cutoff points: positive CT if short axis ≥10 mm and positive PET if SUV >2.5. (B) ROC curve cutoff points: positive CT if short axis ≥2.5 mm and positive PET if SUV >0.5. (C) Sensitivity, specificity, predictive values, and percentage agreement for each PET cutoff point.