Research Article
Study on Steel Content Estimation of Reinforced Concrete Rectangular Pool Wall
Table 4
Rebar configuration and steel content selected by the principle of minimizing reinforcement area.
| Wall thickness | 250 | 300 | 350 | 400 | 450 | 500 | 550 | 600 | 750 | 800 |
| Actual rebar configuration | φ25@100 | φ22@100 | φ20@100 | φ22@125 | φ20@125 | φ25@200 | φ16@100 | φ14@100 | φ14@100 | φ16@125 | Actual reinforcement area | 4910 | 3800 | 3140 | 3040 | 2512 | 2455 | 2010 | 1540 | | 1608 | Steel content | 1.96% | 1.27% | 0.90% | 0.76% | 0.56% | 0.49% | 0.37% | 0.26% | 0.21% | 0.20% |
|
|