CT-MR Image Fusion for Post-Implant Dosimetry Analysis in Brain Tumor Seed Implantation- a Preliminary Study

Table 2

Volume and dosimetry on CT and fusion images.

Image typeCasesCTVExternal V100%V100%D90
RangeRangeRangeRange

CT1638.4 ± 35.23.70-1243.73 ± 3.410.50-12.379.8 ± 13.046.1-96.386.7 ± 16.457.0-114
Fusion34.3 ± 33.62.50-1224.83 ± 4.680.70-17.089.2 ± 8.6060.5-99.0101 ± 9.490.0-122
Ratio fusion/CT0.85 ± 0.100.60-0.981.32 ± 0.341.02-2.401.13 ± 0.121.01-1.421.19 ± 0.171.01-1.65
t-5.8323.7644.5664.316
p<0.0010.002<0.0010.001

H0: ratio = 1. = mean±standard deviation; CTV = clinical target volume; external V100 = the volume of the V100 dose cloud outside the target volume; %D90 = the minimum dose received by 90% of the CTV expressed as a percentage of the prescription dose; %V100 = the percentage of the CTV covered by 100% of the prescription dose.