[Retracted] Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy
Table 5
The correlation of dry eye indices and CL fitting characteristics at different time points.
Temporal lag△1w
Conjunctival coverage△1w
Decentration △1w
Blink-induced movement△1w
r
p
r
p
r
p
r
p
OSDI△1w
-0.473
0.088
0.139
0.636
0.178
0.543
0.614
0.020
Schirmer I test △1w
-0.306
0.288
-0.129
0.661
-0.388
0.171
0.570
0.033
TBUT△1w
-0.073
0.805
-0.317
0.269
-0.374
0.187
0.730
0.003
OSDI△1 m
-0.481
0.082
0.484
0.08
0.423
0.131
0.233
0.422
Schirmer I test △1 m
-0.202
0.488
0.258
0.373
0.131
0.655
0.167
0.569
TBUT△1 m
-0.324
0.259
-0.410
0.146
-0.137
0.642
0.150
0.608
OSDI△3 m
-0.407
0.148
0.140
0.633
0.461
0.097
0.119
0.686
Schirmer I test △3 m
-0.345
0.228
0.087
0.768
-0.051
0.861
-0.170
0.560
TBUT△3 m
0.544
0.044
-0.259
0.372
0.164
0.575
-0.027
0.928
OSDI△6 m
-0.629
0.016
0.130
0.658
0.450
0.106
0.577
0.031
Schirmer I test △6 m
-0.172
0.555
-0.134
0.648
-0.033
0.911
0.061
0.836
TBUT△6 m
-0.246
0.396
0.207
0.478
0.177
0.546
0.533
0.050
OSDI = ocular surface disease index; TBUT = tear break-up time. △value of dry eye indices: the difference between baseline and each time point. △value of CL fitting characteristics: the difference between 1 day and each time point. Pearson correlation coefficient (r) was used to analyze the associations between variables. : P <0.05.