Research Article
Response Time Threshold for Predicting Outcomes of Patients with Out-of-Hospital Cardiac Arrest
Table 3
Receiver operating characteristic (ROC) curve analysis of the optimal response time threshold for predicting survival to hospital discharge.
| Situation | Survival to hospital discharge | Threshold (minutes) | AUC | Lower | Upper | |
| Overall | 6.2 | 0.618 | 0.582 | 0.654 | <0.001 | Witnesses | With | 6.2 | 0.609 | 0.570 | 0.647 | <0.001 | Without | 4.2 | 0.643 | 0.544 | 0.743 | <0.001 | Cardiac arrest location | Public | 7.2 | 0.628 | 0.576 | 0.681 | <0.001 | Residence | 6.1 | 0.611 | 0.563 | 0.66 | <0.001 | Bystander CPR | With | 6.3 | 0.588 | 0.537 | 0.64 | 0.001 | Without | 6.1 | 0.655 | 0.606 | 0.703 | <0.001 | Attended by EMS-paramedic | With | 6.2 | 0.635 | 0.581 | 0.689 | <0.001 | Without | 5.0 | 0.605 | 0.558 | 0.653 | <0.001 | Defibrillation by AED | With | 6.2 | 0.619 | 0.568 | 0.669 | <0.001 | Without | 5.0 | 0.632 | 0.572 | 0.675 | <0.001 | Age | <80 years | 6.3 | 0.627 | 0.589 | 0.665 | <0.001 | ≥80 years | 5.1 | 0.588 | 0.524 | 0.651 | 0.007 |
|
|