Research Article
Experimental Study and Percolation Analysis on Seepage Characteristics of Fractured Coal and Sandstone Based on Real-Time Micro-CT
Figure 4
Seepage test system for real-time CT scanning and its schematic: ① water pump, ② accumulator, ③ pressure meter, ④ and ⑤ valve, ⑥ mini triaxial seepage testing machine, ⑦ confining pressure input line, and ⑧ seepage pressure input line.