Research Article
Gas Displacement Engineering Test by Combination of Low and Medium Pressure Injection with Liquid CO2 in High Gas and Low Permeability Coal Seam
Table 4
Table of medium pressure injection parameters.
| Drilling name | Volume of injection (m3) | Rate of flow (m3/min) | Pressure rise rate (MPa/min) | Maximum pressure (MPa) | Dwell (time/min) | Depressurization rate (MPa/min) | Minimum pressure (MPa) |
| 1#1M | 2.0 | 0.018–0.025 | 0.048 | 3.16 | 25 | 0.038 | 0.48 | 1#2M | 2.0 | 0.020–0.025 | 0.090 | 3.28 | 15 | 0.005 | 2.73 | 2#1M | 2.0 | 0.015–0.020 | 0.040 | 5.30 | 30 | 0.027 | 1.34 | 2#2M | 2.0 | 0.015–0.025 | 0.067 | 5.90 | 25 | 0.010 | 3.50 |
|
|