Research Article
Sealing Form and Failure Mechanism of Deep In Situ Rock Core Pressure-Maintaining Controller
Table 2
Parameters used in the pressure leakage rate test.
| Object | Group number | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| Test chamber | Initial pressure (MPa) | 15.9 | 22.4 | 31.9 | 41 | 50 | 61.7 | 71 | 80.8 | 89.8 | 99.1 | Time (s) | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
| Conical structure | Initial pressure (MPa) | 5.7 | 14.3 | 20.8 | 25.1 | 30.2 | 35.3 | 40.7 | 45.9 | 0 | 0 | Time (s) | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 0 | 0 |
| Wedge structure | Initial pressure (MPa) | 14.9 | 19.6 | 30.6 | 40.3 | 49.1 | 60.4 | 70.6 | 79.6 | 90.6 | 98 | Time (s) | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 | 1-60 |
|
|