Design of the Box-Behnken design table for frost heaving force measurement.
| Run | A-FW (mm) | B-FL (mm) | C-CT (/) | D-RL (/) | FHF (MPa) |
| 1 | 2 | 24 | 1 | 0 | 11.17 | 2 | 1 | 24 | 1 | 1 | 4.73 | 3 | 1 | 36 | 1 | 0 | 8.62 | 4 | 2 | 36 | 0 | 0 | 12.31 | 5 | 3 | 24 | 1 | 1 | 6.62 | 6 | 2 | 24 | 0 | 1 | 5.85 | 7 | 2 | 24 | 1 | 0 | 11.17 | 8 | 2 | 24 | 1 | 0 | 11.17 | 9 | 1 | 24 | 0 | 0 | 8.11 | 10 | 3 | 36 | 1 | 0 | 14.11 | 11 | 3 | 24 | 1 | -1 | 5.01 | 12 | 2 | 12 | 1 | 1 | 7.45 | 13 | 2 | 12 | 0 | 0 | 5.08 | 14 | 2 | 24 | 2 | 1 | 13.32 | 15 | 2 | 12 | 1 | -1 | 1.96 | 16 | 2 | 36 | 1 | -1 | 2.67 | 17 | 2 | 36 | 1 | 1 | 13.77 | 18 | 2 | 36 | 2 | 0 | 15.62 | 19 | 1 | 24 | 2 | 0 | 10.34 | 20 | 3 | 24 | 2 | 0 | 16.08 | 21 | 3 | 24 | 0 | 0 | 13.72 | 22 | 2 | 24 | 1 | 0 | 11.17 | 23 | 1 | 12 | 1 | 0 | 9.31 | 24 | 2 | 24 | 0 | -1 | 6.61 | 25 | 2 | 24 | 2 | -1 | 7.68 | 26 | 2 | 12 | 2 | 0 | 12.37 | 27 | 3 | 12 | 1 | 0 | 12.07 | 28 | 2 | 24 | 1 | 0 | 11.17 | 29 | 1 | 24 | 1 | -1 | 3.28 |
|
|