Research Article
Development and Application of an Intelligent Evaluation and Control Platform for Tunnel Smooth Blasting
Table 3
Hole arrangement parameters.
| Location | Serial number | Name | Hole depth (m) | Blastholes | Explosive charge in per hole (kg) | Initiation order | Millisecond stage |
| Whole section | 1 | Cutting hole | 2.8 | 10 | 2.4 | 1 | 1 | 2 | Auxiliary hole | 2.5 | 8 | 1.8 | 2 | 3 | 3 | Auxiliary hole | 2.5 | 16 | 1.5 | 3 | 5 | 4 | Auxiliary hole | 2.5 | 25 | 1.5 | 4 | 7 | 5 | Bottom hole | 2.5 | 9 | 1.2 | 5 | 9 | 6 | Side borehole | 2.5 | 29 | 0.75 | 6 | 11 |
|
|