Research Article
Oil-Based Drilling Fluid Plugging Method for Strengthening Wellbore Stability of Shale Gas
Table 9
Temperature resistance evaluation results of strong plugging drilling fluid.
| System | Condition | AV (mPa·s) | PV (mPa·s) | YP (Pa) | Gel10/Gel10 (Pa/Pa) | FLAPI (mL) |
| Formula CN-5 | Temperature resistance | Before aging | 67.5 | 52 | 15.5 | 8.18/15.33 | 0.2 | 135°C/16 h | 75 | 60 | 15 | 3.58/23.51 | 0 | Temperature endurance | Before aging | 67.5 | 52 | 15.5 | 8.18/15.33 | 0.2 | 125°C/32 h | 78 | 64 | 14 | 10.22/15.33 | 0 |
|
|