Research Article

Synthesis of a Novel Filtrate Reducer and Its Application in Water-Based Drilling Fluid for Ultra-High-Temperature Reservoirs

Table 5

Comparison of fluid loss controlling of fluid loss agents in fresh water slurry.

Experimental slurryTest conditionsAV (mPa·s)PV (mPa·s)YP (Pa)API (mL)

3-1 basic slurryRoom temperature8.535.524.0
Room temperature after 220°C/16 h73434.0
Room temperature after 245°C/16 h8.580.541.0
Room temperature6030308.4
Room temperature after 220°C/16 h41312.4
Room temperature53213210.6
Room temperature after 245°C/16 h1110120.6
Room temperature4028127.8
Room temperature after 245°C/16 h1714311.0