Research Article

In-situ Combustion Simulation from Laboratory to Field Scale

Table 1

H/C ratio () and CO/CO2 ratio () values for the five kinetic cell (RTO) experiments.

Temperature range [°C]H/C ratioCO/CO2 ratio

Low-temperature oxidation195–3503.0–5.30.50–1.21
High-temperature oxidation350–5000.5–2.00.15–0.34