Research Article
Expansion Velocity Model of Steam-Assisted Gravity Drainage considering Thermal Convection
Table 1
Model verification parameter table.
| | Item | Value | Item | Value |
| | Porosity | 0.3 | Steam temperature | 240°C | | Permeability | | Steam chamber angle | 45° | | Reservoir thickness | 20 m | Chamber temperature | 280°C | | Caprock thickness | 15 m | Reservoir temperature | 30°C | | Well spacing | 100 m | Reservoir density | 2500 kg·m-3 | | Horizontal well length | 350 m | Convective phase density | 1500 kg·m-3 | | Reservoir pressure | 1.2 MPa | Moving speed of steam | | | Oil viscosity | | Thermal diffusivity | | | Water specific heat capacity | 4200 J/(kg·K) | Original oil saturation | 0.85 | | Oil specific heat capacity | 1800 J/(kg·K) | Connate-water saturation | 0.15 | | Thermal conductivity | 1.5 W/(m·°C) | Relative permeability of bound water oil phase | 0.85 | | Injection pressure | 1.80 MPa | Absolute reservoir permeability | | | Pressure–viscosity factor | 2 | | | | Temperature–viscosity factor | 3 | Relative permeability of water phase under residual oil | 0.03 |
|
|