Research Article
Investigation of the Ultrasonic Stimulation Performance on Permeability Enhancement in Coal Seam: Field Tests and In Situ Permeability Evaluation
Table 2
Data analysis of gas flowrate in borehole.
| Zone | Borehole | Distance from the antireflection borehole | Average gas flowrate | Increment |
| Zone 0 | Average | / | 0.041 m3/min | / | Zone 1 | #1 | 8 m | 0.0492 m3/min | 20% | #2 | 4 m | 0.0791 m3/min | 93% | #3 | 2 m | 0.0829 m3/min | 102% | Zone 2 | #1 | 8 m | 0.0757 m3/min | 85% | #2 | 4 m | 0.0836 m3/min | 104% | #3 | 2 m | 0.0843 m3/min | 106% |
|
|