Research Article
Investigation of the Ultrasonic Stimulation Performance on Permeability Enhancement in Coal Seam: Field Tests and In Situ Permeability Evaluation
Table 2
Data analysis of gas flowrate in borehole.
| | Zone | Borehole | Distance from the antireflection borehole | Average gas flowrate | Increment |