Research Article
Experimental and Finite Element Study on 7A04 Aluminum Alloy Tube Confined High Strength Concrete Long Column
Table 5
Comparison of test values and finite element calculated values.
| Specimen label | Test values /kN | Simulated values /kN | |
| AHCSE0-1 | 598 | 568 | 1.05 | AHCSE0-2 | 540 | 511 | 1.06 | AHCSE0-3 | 470 | 467 | 1.01 | AHCSE15-1 | 363 | 338 | 1.07 | AHCSE15-2 | 311 | 289 | 1.07 | AHCSE15-3 | 257 | 241 | 1.07 | AHCSE30-1 | 220 | 224 | 0.98 | AHCSE30-2 | 182 | 191 | 0.95 | AHCSE30-3 | 154 | 158 | 0.98 |
|
|