Comparison of test values and theoretical formula calculation values.
| Specimen label | Test values /kN | Formula calculated values /kN | |
| AHCSE0-1 | 598 | 617 | 0.968 | AHCSE0-2 | 540 | 549 | 0.982 | AHCSE0-3 | 470 | 444 | 1.057 | AHCSE15-1 | 363 | 368 | 0.984 | AHCSE15-2 | 311 | 328 | 0.947 | AHCSE15-3 | 257 | 265 | 0.968 | AHCSE30-1 | 220 | 241 | 0.911 | AHCSE30-2 | 182 | 214 | 0.846 | AHCSE30-3 | 154 | 173 | 0.941 |
|
|
is the calculated value of the theoretical formula. |