Calculation parameters of bolt.

Bolt diameterSectional areaMortar diameterMortar perimeterBolt tensile strengthBolt prestress

22 mm3.50 cm2100 mm0.314 m250 kN60 kN
Bolt lengthMortar cohesionMortar frictionMortar stiffnessBolt numberAdjacent bolts angle
3 m20 kPa25°22.33 MN/m221