Research Article
Comparison of Mechanical Properties and Sensitivity of Compressive and Flexural Strength of Artificial Frozen Sand
Table 1
Test results of mechanical properties of artificial frozen soil.
| Moisture content (%) | Curing temperature (°C) | No. | Compressive strength (MPa) | Mean value (MPa) | No. | Break off strength (MPa) | Mean value (MPa) |
| 12 | −10 | C1#-1 | 3.00 | 3.17 | F1#-1 | 1.05 | 1.16 | C1#-2 | 3.23 | F1#-2 | 1.19 | C1#-3 | 3.27 | F1#-3 | 1.23 | −15 | C2#-1 | 3.06 | 3.57 | F2#-1 | 1.46 | 1.63 | C2#-2 | 3.60 | F2#-2 | 1.69 | C2#-3 | 4.04 | F2#-3 | 1.75 | −20 | C3#-1 | 3.79 | 4.24 | F3#-1 | 1.94 | 2.06 | C3#-2 | 4.45 | F3#-2 | 2.03 | C3#-3 | 4.47 | F3#-3 | 2.21 |
| 15 | −10 | C4#-1 | 5.41 | 5.50 | F4#-1 | 1.47 | 1.61 | C4#-2 | 5.52 | F4#-2 | 1.59 | C4#-3 | 5.56 | F4#-3 | 1.78 | −15 | C5#-1 | 6.37 | 6.87 | F5#-1 | 3.49 | 3.77 | C5#-2 | 7.04 | F5#-2 | 3.82 | C5#-3 | 7.21 | F5#-3 | 3.99 | −20 | C6#-1 | 10.37 | 10.79 | F6#-1 | 5.28 | 5.65 | C6#-2 | 10.80 | F6#-2 | 5.73 | C6#-3 | 11.20 | F6#-3 | 5.95 |
| 18 | −10 | C7#-1 | 6.02 | 6.15 | F7#-1 | 2.73 | 2.84 | C7#-2 | 6.07 | F7#-2 | 2.82 | C7#-3 | 6.35 | F7#-3 | 2.97 | −15 | C8#-1 | 8.12 | 8.27 | F8#-1 | 4.43 | 4.84 | C8#-2 | 8.26 | F8#-2 | 4.83 | C8#-3 | 8.42 | F8#-3 | 5.26 | −20 | C9#-1 | 10.73 | 10.83 | F9#-1 | 5.90 | 6.44 | C9#-2 | 10.83 | F9#-2 | 6.56 | C9#-3 | 10.92 | F9#-3 | 6.87 |
|
|