Research Article
Application of GPR Underground Pipeline Detection Technology in Urban Complex Geological Environments
Table 2
Location of underground pipelines in section β.
| Line number | β-1 | β-2 | β-3 | β-4 |
| The top of the underground pipeline is at the horizontal position of the survey line (m) | 3.554 | 1.796 | 3.493 | 0.963 | The underground pipeline is located at the horizontal position of the survey line (m) | 2.732 to 3.930 | 1.472 to 2.446 | 3.022 to 3.895 | 0.569 to 1.450 | Buried depth of underground pipeline from ground (m) | 0.909 | 1.204 | 1.258 | 1.646 | Underground pipeline width (m) | 1.199 | 1.075 | 0.874 | 0.882 |
|
|