Research Article
Development of the Large-Tonnage Pressure-Type Prestressed Anchor Cable with BFRP for Geotechnical Engineering and Its Mechanical Properties
Table 2
Strength test of the “BFRP-connector-strand.”
| Steel strand structure for the “BFRP-connector-strand” | Strength of the “BFRP-connector-strand” | The failure mode of the “BFRP-connector-strand” |
| Normal steel strand | 146.00 kN | Steel strand pulled out from the connector (Figure 3(a)) | Quartz sand-coated steel strand | 165.92 kN | Steel strand pulled out from the connector | Sputtering-treated steel strand | 185.66 kN | Steel strand pulled out from the connector | Surface-indented steel strand | 336.97 kN | BFRP tendon rupture (Figure 3(b)) |
|
|