Research Article

Development of the Large-Tonnage Pressure-Type Prestressed Anchor Cable with BFRP for Geotechnical Engineering and Its Mechanical Properties

Table 2

Strength test of the “BFRP-connector-strand.”

Steel strand structure for the “BFRP-connector-strand”Strength of the “BFRP-connector-strand”The failure mode of the “BFRP-connector-strand”

Normal steel strand146.00 kNSteel strand pulled out from the connector (Figure 3(a))
Quartz sand-coated steel strand165.92 kNSteel strand pulled out from the connector
Sputtering-treated steel strand185.66 kNSteel strand pulled out from the connector
Surface-indented steel strand336.97 kNBFRP tendon rupture (Figure 3(b))