Research Article

Research on Seepage Characteristics of Y-Shaped Fractures under Different Fracture Roughness

Table 2

Fluid seepage results under different inlet pressures ().

Fracture roughnessInlet pressure (Pa)Flow rate of outlet A (cm3/s)Flow velocity of outlet A (cm/s)Flow rate of outlet B (cm3/s)Flow velocity of outlet B (cm/s)

1.0-1.0-1.0501.165.801.155.75
1002.4912.462.4512.25
1504.0420.193.9219.59
2005.8829.405.6928.43
1.0-1.1-1.1501.165.781.155.76
1002.4212.122.4112.05
1503.8419.193.8119.05
2005.5227.605.4727.34
1.0-1.2-1.2501.115.561.115.54
1002.1710.862.1610.82
1503.1715.843.1515.76
2004.1020.514.0820.39
1.0-1.3-1.3501.035.171.035.16
1001.839.161.839.16
1502.4712.332.4712.34
2003.2116.043.2116.05