Research Article
Research on Seepage Characteristics of Y-Shaped Fractures under Different Fracture Roughness
Table 3
Fluid seepage results under different inlet pressures.
| Fracture roughness | Inlet pressure (Pa) | Flow rate of outlet A (cm3/s) | Flow velocity of outlet A (cm/s) | Flow rate of outlet B (cm3/s) | Flow velocity of outlet B (cm/s) |
| 1.0-1.0-1.1 | 50 | 1.16 | 5.79 | 1.15 | 5.74 | 100 | 2.51 | 12.57 | 2.38 | 11.88 | 150 | 4.08 | 20.42 | 3.74 | 18.72 | 200 | 5.93 | 29.64 | 5.38 | 26.90 | 1.0-1.0-1.3 | 50 | 1.23 | 6.16 | 0.97 | 4.84 | 100 | 2.74 | 13.72 | 1.60 | 8.00 | 150 | 4.35 | 21.74 | 2.01 | 10.07 | 200 | 5.93 | 29.64 | 2.32 | 11.62 | 1.0-1.0-1.5 | 50 | 1.34 | 6.70 | 0.85 | 4.37 | 100 | 2.91 | 14.56 | 1.31 | 6.56 | 150 | 4.48 | 22.38 | 1.60 | 8.02 | 200 | 5.98 | 29.89 | 1.83 | 9.16 |
|
|