Measured permeability of C50S1.2 test block in dynamic loading and unloading test (the confining pressure value is 1 MPa).

Axial Load (MPa)Loading speed, 0.5 MPa/sLoading speed, 1.0 MPa/sLoading speed, 1.5 MPa/sLoading speed, 3.0 MPa/s
Measured value of permeability (e − 16 m2)

12.552.682.662.74
53.463.607.1513.55
103.554.5411.3429.39
153.685.8721.4876.34
205.457.7728.35122.37
104.345.2417.6856.54
53.774.2810.2443.56
13.343.778.1739.75