Research Article

Calculation of Cementing ECD for Well Annuli with Narrow or Varied Radial Sizes

Table 1

Irrelevance verifications for both the grid size and the axial computational domain.

No.

1300.510723579613.490
2300.110182314,90413.998
3300.15184659,61614.190
4300.055244679,48814.227
5300.0154146135,79214.227
6300.00255846192,09614.279
7300.00156646218,59214.282
8600.0155392351,07214.288
91200.01541183540,21614.289