Influence of the strength enhancement factor on the overlying strata structure stability.

Strength enhancement factorOverlying load (MPa)Displacement (mm)Fracture height (m)
Key strataLower water-resistingKey strataLower water-resisting

1.05.414.473968.003877.0055.00
1.25.424.403963.003879.0055.00
1.50.874.42207.70112.2053.88
2.00.715.89120.1042.7539.25