Research Article

Mechanism and Control of Water–Rock Coupling-Induced Disaster when Mining below the Unconsolidated Confined Aquifer

Table 7

Influence of the height of the waterproof coal pillar on the overlying strata structure stability.

Height of waterproof coal pillar (m)Overlying load (MPa)Displacement (mm)Fracture height (m)
Key strataLower water-resistingKey strataLower water-resisting

555.414.473968.003877.0055.00
703.494.593956.003839.0070.00
850.605.26177.6045.7264.75
1000.596.83151.9033.4874.13