Research Article

A New Method to Predict Shock-Type Coal-Gas Outburst Disaster and Its Application

Table 1

Disturbance intensity index of shock-type coal and gas outburst by hard roof.

Serial numberThickness, mCompressive strength, MPaDistance between hard rock and coal seam, mDisturbance intensity index

1≥30≥60<206
215~30≥60<205
3<15≥60<204
4≥30≥6020~405
515~30≥6020~404
6<15≥6020~403
7≥30≥60≥404
815~30≥60≥403
9<15≥60≥402
10≥3035~60<205
1115~3035~60<204
12<1535~60<203
13≥3035~6020~404
1415~3035~6020~403
15<1535~6020~402
16≥3035~60≥403
1715~3035~60≥402
18<1535~60≥401