Research Article
A Trans-Scale Study on the Influence of Water Content and Particle Size on Matric Suction
Table 1
The measured and calculated results for the equal sphere system.
| Diameter/mm | Liquid volume/μL | Pore volume/mm3 | Saturation/% | Volumetric water content/% | left/mm | right/mm | equal/mm | /mm | Ψ/pa |
| 3 | 0.1 | 4.09 | 2.44 | 1.16 | 0.33 | 0.34 | 0.34 | 0.58 | 76.67 | 0.2 | 4.89 | 2.33 | 0.43 | 0.43 | 0.43 | 0.75 | 61.37 | 0.5 | 12.22 | 5.82 | 0.52 | 0.51 | 0.52 | 0.77 | 39.34 | 1 | 24.45 | 11.65 | 0.61 | 0.68 | 0.65 | 0.79 | 17.17 | 1.5 | 36.67 | 17.47 | | | | | |
| 4 | 0.1 | 16.76 | 0.60 | 0.29 | 0.35 | 0.33 | 0.34 | 0.73 | 98.99 | 0.2 | 1.19 | 0.57 | 0.42 | 0.42 | 0.42 | 0.85 | 75.88 | 0.5 | 2.99 | 1.42 | 0.52 | 0.50 | 0.51 | 0.97 | 58.58 | 1 | 5.97 | 2.84 | 0.66 | 0.60 | 0.63 | 1.02 | 38.24 | 1.5 | 8.96 | 4.27 | 0.63 | 0.77 | 0.70 | 1.05 | 36.75 |
| 5 | 0.1 | 32.72 | 0.31 | 0.15 | 0.35 | 0.35 | 0.35 | 0.78 | 99.23 | 0.2 | 0.61 | 0.29 | 0.41 | 0.43 | 0.42 | 0.88 | 78.41 | 0.5 | 1.53 | 0.73 | 0.50 | 0.48 | 0.49 | 0.99 | 64.94 | 1 | 3.06 | 1.46 | 0.59 | 0.62 | 0.61 | 1.08 | 44.95 | 1.5 | 4.58 | 2.18 | 0.64 | 0.70 | 0.67 | 1.12 | 37.78 |
|
|